| Sign In | Join Free | My insurersguide.com |
|
Measurement Range : 1.2bar~800mbar
Operating Temperature : -40℃~+55℃
Description : 1.2bar~800mbar Gas Sensor RoHS
Mfr. Part # : PS4-H2-1000
Model Number : PS4-H2-1000
The SGX series of PS1 and PS4 Electrochemical gas sensors utilize a revolutionary 'Solid Polymer Electrolyte' technology based on catalytic reaction principles. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. They are characterized by their very small size, high sensitivity, low power consumption, and minimal cross-sensitivity to other gases. Key applications include ambient monitoring, sensitive leak detection, battery production, semiconductor manufacturing, data center protection, and propellant detection.
| Model | PS1-H2-1000 | PS4-H2-1000 |
|---|---|---|
| Sensitivity | 11 ± 3 nA / ppm | |
| Measurement Range | 0 1000 ppm | |
| Zero Current | ± 100 nA | |
| Maximum Overload | 2000 ppm | |
| Response Time | T50 < 10s, T90 < 30s | |
| Repeatability | 1% | |
| Lower Detectable Limit (LDL) | ≤ 2 ppm | |
| Linear Range | 1000 ppm | |
| Resolution (16Bit ADC) | 0.1ppm | |
| Operating Humidity Range | 15-95% RH | |
| Pressure Range | 800 to 1200 hPA | |
| Storage Temperature | 0 to 20°C | |
| Temperature Range | -40°C to +55°C | |
| Recommended Load Resistor | 100 Ω | |
| Bias Voltage | 0 mV | |
| Warm Up Time | < 60 s | |
| Long-Term Drift | < 1 %/month | |
| Zero Drift in Clean Air | < 10 ppm | |
| Storage Life | 12 months | |
| Weight | < 0.7g | < 6g |
|
|
High Precision Amphenol PS4-H2-1000 Electrochemical Sensor with Solid Polymer Electrolyte Technology Images |