| Sign In | Join Free | My insurersguide.com |
|
working temperature : -40℃~+85℃
Current Range : ±200A
Voltage - Supply : -15V~-12V;12V~15V
Response Time (tr) : 500ns
Bidirectional Current Detection : Support
Description : ±200A Through Hole Current Sensors RoHS
Mfr. Part # : CSNR161-006
Model Number : CSNR161-006
Package : Through Hole
Honeywell Sensing and Control (S&C) offers a comprehensive range of current sensors designed to monitor alternating (AC) and direct (DC) current with superior accuracy and reduced cost. These sensors provide advantages such as thru-hole design, fast response times, output voltage isolation from input, minimum energy dissipation, and enhanced reliability with adjustable performance and built-in temperature compensation. Applications span variable speed drives, overcurrent protection, ground fault detectors, current feedback control systems, robotics, UPS and telecommunication power supplies, welding power supplies, battery management systems, and wattmeters.
| Series | Type | Sensed Current Range | Output | Response Time | Accuracy | Operating Temperature | Supply Voltage |
| CSDA | Digital/Inductive | 0.5 A.t. nom., 3.5 A.t. nom. | Digital (TTL logic level, open collector) | 100 s | better than 0.5 % | -25 C to 85 C [-13 F to 185 F] | 6 Vdc to 16 Vdc |
| CSNX | Closed Loop | 56 A | Current | < 0.2 s | 0.24 % | -40 C to 85 C [-40 F to 185 F] | 4.75 Vdc to 5.25 Vdc |
| CSNA | Closed Loop | 70 A, 90 A, 100 A | Current | < 1 s | 0.5 % | 0 C to 70 C [32 F to 158 F] | 13 Vdc, 15 Vdc |
| CSNF | Closed Loop | 150 A, 180 A, 200 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12 Vdc to 15 Vdc |
| CSNB | Closed Loop | 100 A | Current | < 1 s | 0.5 % | 0 C to 70 C [32 F to 158 F] | 15.0 Vdc |
| CSNC | Closed Loop | 90 A | Current | < 1 s | 0.5 % | -25 C to 85 C [-13 F to 185 F] | 13.0 Vdc |
| CSNE | Closed Loop | 36 A, 90 A | Current | < 1 s | 0.5 % | 0 C to 70 C [32 F to 158 F] | 12 Vdc to 15 Vdc |
| CSNG | Closed Loop | 180 A, 200 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 15.0 Vdc |
| CSNJ | Closed Loop | 600 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 18.0 Vdc |
| CSNK | Closed Loop | 1200 A | Current | < 1 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 15 Vdc to 18 Vdc |
| CSNL | Closed Loop | 600 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 18.0 Vdc |
| CSNM | Closed Loop | 1000 A | Current | < 1 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 18.0 Vdc |
| CSNP | Closed Loop | 90 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 15.0 Vdc |
| CSNS | Closed Loop | 320 A, 600 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12 Vdc to 18 Vdc |
| CSNR | Closed Loop | 200 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 15.0 Vdc |
| CSNT | Closed Loop | 150 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 15.0 Vdc |
| CSLS | Open Loop | 60 A | Sink/Source | 3 s | 15 mV/AT 2 mV/AT @ 5 Vdc | -25 C to 100 C [-13 F to 212 F] | 4.5 Vdc to 10.5 Vdc |
| CSLT | Open Loop | 100 A | Sink/Source | 3 s | 15 mV/AT 2 mV/AT @ 5 Vdc | -25 C to 100 C [-13 F to 212 F] | 4.5 Vdc to 10.5 Vdc |
| CSLW | Open Loop | 1 A, 5 A, 40 mA, 200 mA | Sink/Source | 3 s | various | -25 C to 100 C [-13 F to 212 F] | 4.5 Vdc to 10.5 Vdc |
| CSCA-A | Open Loop | 150 A, 300 A | Voltage | 3 s to 7 s | -10 C to 80 C [14 F to 176 F] | 15 Vdc 5 % | |
| CSLA | Open Loop | 600 A, 900 A | Voltage/Sink/Source | 3 s, 8 s | various | -25 C to 85 C [-13 F to 185 F] | 8 Vdc to 16 Vdc |
| CSLH | Open Loop | 57 A to 950 A, 9 A, 45 A | Sink/Source | 3 s | 18.5 mV N* 3.5 mV N* @ 5 Vdc or 282 mV N* -42, +82 mV N* @ 10 Vdc | -25 C to 85 C [-13 F to 185 F] | 6 Vdc to 12 Vdc; 4.5 Vdc to 10.5 Vdc |
|
|
High accuracy current sensor Honeywell CSNR161-006 designed for overcurrent protection and ground fault detection systems Images |