| Sign In | Join Free | My insurersguide.com |
|
working temperature : -10℃~+70℃
Current Range : ±300A
Voltage - Supply : -15V~-12V;12V~15V
Band Width : 100kHz
Response Time (tr) : 1us
Bidirectional Current Detection : Support
Description : ±300A Current Sensors RoHS
Mfr. Part # : LT208-S7/SP1
Model Number : LT208-S7/SP1
The LEM LT 208-S7/SP1 is an insulated current sensor designed for measuring DC, AC, and pulse currents. It utilizes Hall effect technology in a closed-loop (compensated) system, offering excellent accuracy, linearity, low temperature drift, and fast response times. Its design features an insulated housing compliant with UL 94-V0 standards, providing strong interference immunity and current overload capability. This sensor is suitable for various industrial applications including variable speed drives, DC motor traction, battery power, UPS, SMPS, and welding power supplies.
| Parameter | Value | Unit | Notes |
| Product Name | LT 208-S7/SP1 | Current Sensor | |
| Primary Rated RMS Current (IPN) | 200 | A | |
| Primary Current Measuring Range (IPM) | 0 .. 300 | A | |
| Secondary Rated RMS Current (ISN) | 100 | mA | |
| Transduction Ratio (KN) | 1 : 2000 | ||
| Supply Voltage (VC) ( 5 %) | 12 .. 15 | V | |
| Current Consumption (IC) | 28 (@ 12V) + IS | mA | |
| Total Accuracy @ IPN, TA = 25C (XG) | 0.5 | % | |
| Linearity (L) | < 0.1 | % | Typ |
| Electrical Offset Current (IOE) @ IP = 0, TA = 25C | 0.20 | mA | |
| Magnetic Offset Current (IOM) 1) @ IP = 0, overload 3 x IPN | 0.20 | mA | |
| Temperature Drift of IO (IOT) (- 10C .. + 70C) | 0.20 / 0.64 | mA | |
| Reaction Time to 10% of IPN (tra) | < 500 | ns | |
| Response Time to 90% of IPN (tr) 2) | < 1 | s | @ 100 A/s di/dt |
| di/dt Follower Accuracy | > 100 | A/s | |
| Bandwidth (- 3 dB) (BW) | DC .. 100 | kHz | |
| Ambient Operating Temperature (TA) | - 10 .. + 70 | C | |
| Ambient Storage Temperature (TS) | - 25 .. + 80 | C | |
| Secondary Coil Resistance @ TA = 70C (RS) | 21 | ||
| Mass (m) | 82 | g | |
| AC Isolation Test Voltage (Vd) 1), 50 Hz, 1 min | 3.52 | kV | Primary-Secondary |
| Impulse Withstand Voltage (Vw) 1.2/50 s | 6.5 | kV | |
| Creepage Distance (dCp) 2) | 10 | mm | Primary to external surface terminals |
| Electrical Clearance Distance (dCI) 3) | 6 | mm | Primary to external surface terminals |
| Comparative Tracking Index (CTI) (group IIIa) | 275 |
|
|
LEM LT208-S7SP1 insulated current sensor designed for SMPS UPS and variable speed drive applications Images |