| Sign In | Join Free | My insurersguide.com |
|
working temperature : -40℃~+125℃
Current Range : 15A
Voltage - Supply : 4.5V~5.5V
Band Width : 120kHz
Current Terminal Resistance : 1mΩ
Response Time (tr) : 4us
Sensitivity : 90mV/A
Bidirectional Current Detection : Support
Description : 15A 90mV/A SOIC-16-300mil Current Sensors RoHS
Mfr. Part # : ACS720KLATR-15AB-T
Model Number : ACS720KLATR-15AB-T
Package : SOIC-16-300mil
The ACS720 is a high-accuracy, Hall-effect-based current sensor IC designed for industrial and consumer applications, particularly in motor control and power inverter stages. It offers high isolation with a reduced bill of materials due to its proprietary SOIC16W package. Operating from a single 5V supply, the ACS720 provides a 0-3V output swing with a stable 1.5V zero-current output, compatible with 3.3V ADCs. Its high PSRR effectively rejects noise in demanding environments. The device features dual, user-configurable fault functions (fast and slow) for short-circuit and overcurrent detection, with fault levels set via an external resistor divider. Integrated differential current sensing rejects external magnetic fields, simplifying board layout in 3-phase motor applications. The ACS720 boasts patented integrated digital temperature compensation for high accuracy over temperature and a low 1.0 m primary conductor resistance for minimal power loss.
| Model | Sensing Range (IPR) | Sensitivity (Typ) | Fast Fault Mask Time (Typ) | Operating Temperature (TA) |
|---|---|---|---|---|
| ACS720KLATR-15AB-T | 15 A | 90 mV/A | 0 s | 40 to 125 C |
| ACS720KLATR-15AB-T-4 | 15 A | 90 mV/A | 1.5 s | 40 to 125 C |
| ACS720KLATR-35AB-T | 35 A | 38.5 mV/A | 0 s | 40 to 125 C |
| ACS720KLATR-35AB-T-4 | 35 A | 38.5 mV/A | 1.5 s | 40 to 125 C |
| ACS720KLATR-65AB-T | 65 A | 20.5 mV/A | 0 s | 40 to 125 C |
| ACS720KLATR-65AB-T-4 | 65 A | 20.5 mV/A | 1.5 s | 40 to 125 C |
| ACS720KLATR-80AB-T | 80 A | 16 mV/A | 0 s | 40 to 125 C |
| ACS720KLATR-80AB-T-4 | 80 A | 16 mV/A | 1.5 s | 40 to 125 C |
| Characteristic | Symbol | Conditions | Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 4.5 | 5.0 | 5.5 | V | |
| Supply Current | ICC | VCC = 5.0 V, output open | 13 | 16 | mA | |
| Primary Conductor Resistance | RIP | TA = 25C | 1.0 | m | ||
| Power-On Time | tPO | TA = 25C | 70 | s | ||
| Fault Power-On Time | tPO(FAULT) | 270 | s | |||
| Internal Bandwidth | BW | Small signal 3 dB; CL = 1 nF | 120 | kHz | ||
| Power Supply Rejection Ratio (DC to 1 kHz) | PSRR | 40 | dB | |||
| Common Mode Field Rejection Ratio | CMFR | Magnetic field perpendicular to Hall plates | -45 | dB | ||
| Dielectric Strength Test Voltage | VISO | Agency type-tested for 60 seconds per UL 60950-1 | 3600 | VRMS | ||
| Working Voltage for Basic Isolation | VWVBI | According to UL 60950-1 | 870 VPK or 616 VRMS | V | ||
| Junction-to-Ambient Thermal Resistance | RJA | Mounted on ASEK732/3 evaluation board | 17 | C/W |
The ACS720 features two user-settable overcurrent fault comparators (Fast Fault - FAULT_F, and Slow Fault - FAULT_S) that activate when the absolute input current (IP) exceeds a defined threshold. These are active-low, open-drain outputs. The Fast Fault offers ultrafast response with reduced accuracy, suitable for short-circuit detection. The Slow Fault provides higher accuracy for overload conditions. Fault thresholds are configured using external resistor dividers connected to the VOC_F and VOC_S pins, which are ratiometric to VCC. The VOC pins are sampled at 62.5 kHz, requiring filtering below 31 kHz to prevent aliasing.
Slow Fault Threshold:
IFAULT(S) = [(VOC(S) 0.3 VCC) / (0.4 VCC)] (0.75 IPR) + 0.5 IPR
VOC(S) = [(IFAULT(S) 0.5 IPR) 0.4 VCC] / (0.75 IPR) + (0.3 VCC)
Fast Fault Threshold:
IFAULT(F) = [(VOC(F) 0.3 VCC) / (0.4 VCC)] (1.25 IPR) + 1.0 IPR
VOC(F) = [(IFAULT(F) 1.0 IPR) 0.4 VCC] / (1.25 IPR) + (0.3 VCC)
Fault Response Time (tR(F)) is measured from IP exceeding the fault threshold until the fault pin asserts. Fault Clear Time (tC(F)) is from IP falling below the threshold minus hysteresis (IHYS) until the fault pin deasserts. Hysteresis values (IHYS(FF), IHYS(SF)) are typically 0.06 IPR and 0.05 IPR respectively.
Certain part numbers include a mask time (tMASK) to ignore nuisance current pulses. If the blank time (tB) between pulses is less than 4 s, repetitive pulses may be interpreted as a continuous overcurrent event.
Self-heating due to current flow must be considered. Plots are available for steady-state die temperature rise versus continuous current and maximum continuous current at various ambient temperatures. The maximum junction temperature (TJ(MAX) = 165C) must not be exceeded.
|
|
Allegro ACS720KLATR15ABT hall effect current sensor ic optimized for three phase motor applications Images |